Anchor design to EN 1992-4, step by step
EN 1992-4 (Eurocode 2, Part 4) is the European standard for fastenings in concrete. It replaced the older ETAG 001 Annex C and EOTA TR 029 methods. This guide shows how a post-installed anchor is checked, with a short worked example you can repeat by hand or in AAS.
1. What you need before you start
An anchor design needs three groups of data. The design checks combine them; none of them can be guessed.
- The anchor and its European Technical Assessment (ETA): diameter, embedment depth hef, steel grade, bond strength τRk, minimum spacing and edge distance, and the installation safety factor γinst.
- The concrete: strength class, member thickness, edge distances, and whether it is cracked or uncracked. Without a check that the concrete stays uncracked under all loads, design for cracked concrete.
- The design loads on the fastening: tension NEd, shear VEd and any bending, from the EN 1990 load combinations. For a group of anchors under a base plate, the loads per anchor follow from the plate's equilibrium.
2. The failure modes in tension
EN 1992-4 checks every way the fastening can fail, and the smallest resistance governs. For a bonded (injection) anchor in tension these are:
- Steel failure of the rod: NRk,s = As · fuk, with γMs = 1.2 fuk/fyk ≥ 1.4.
- Concrete cone failure: N0Rk,c = k1 · √fck · hef1.5, with k1 = 7.7 in cracked and 11.0 in uncracked concrete, then reduced for edges, spacing, eccentricity and dense reinforcement.
- Combined pull-out and concrete failure (bond): N0Rk,p = ψsus · τRk · π · d · hef, with τRk from the ETA and ψsus for sustained loads.
- Splitting of the concrete, which need not be checked when the edge distance and member thickness meet the values of the ETA.
For concrete failures the partial factor is γMc = γc · γinst, normally 1.5 × 1.0 = 1.5, unless the ETA gives a higher γinst.
3. Worked example: one bonded anchor in tension
One M12 threaded rod, steel grade 5.8, set with injection resin at hef = 110 mm into cracked C25/30 concrete, at least 165 mm from every edge. Design tension NEd = 15 kN, static, mostly short-term. The bond strength used here, τRk = 7.0 N/mm² in cracked concrete, is an illustrative value: always take it from the ETA of the product you install.
| Check | Characteristic resistance | Partial factor | Design resistance | Utilisation |
|---|---|---|---|---|
| Steel: 84.3 mm² × 500 N/mm² | 42.1 kN | γMs = 1.5 | 28.1 kN | 0.53 |
| Concrete cone: 7.7 × √25 × 110^1.5 | 44.4 kN | γMc = 1.5 | 29.6 kN | 0.51 |
| Bond: 7.0 × π × 12 × 110 | 29.0 kN | γMp = 1.5 | 19.4 kN | 0.78 |
The bond check governs: 15 / 19.4 = 0.78 ≤ 1.0, so the anchor is adequate in tension. Far from the edges, with a single anchor, all the reduction factors equal 1.0 (ψre,N = 0.5 + hef/200 = 1.05 is capped at 1.0). Near an edge, or in a group, the projected areas Ac,N and Ap,N and the factors ψs,N, ψec,N reduce the cone and bond resistances, and the check must be repeated.
4. Shear, and tension with shear
In shear EN 1992-4 checks steel failure with and without a lever arm, concrete pry-out (k8 × the tension resistance of the concrete), and concrete edge failure, which often governs close to an edge. When tension and shear act together, the utilisations are combined, for concrete failures with (βN)1.5 + (βV)1.5 ≤ 1, and for steel failure with (βN)² + (βV)² ≤ 1.
5. Where hand calculation stops
- Groups of anchors under a base plate need the load on each anchor, which depends on the plate stiffness and on the compression zone under the plate.
- Seismic actions need the seismic performance category of the anchor (C1 or C2) and the reduction factors of EN 1992-4 Annex C.
- Fire resistance, fatigue and supplementary reinforcement each have their own rules and values from the ETA.
6. Do this calculation in AAS
AAS performs every check of EN 1992-4 for single anchors and groups: it finds the anchor loads under a rigid or flexible base plate, applies the edge and spacing factors, checks tension, shear and their interaction, and prints a report with each step. It runs in your browser, and your project stays on your own computer.
This guide explains the method; it is not a design. Every fastening must be designed and checked by a qualified engineer with the values of the ETA of the product used.