Wind load on a pergola or canopy to EN 1991-1-4, step by step
A pergola looks light, but wind can lift its roof with a force several times its own weight. Its roof is a canopy in the sense of EN 1991-1-4 (section 7.3): it has air on both sides, so the standard gives net force coefficients for the whole roof. This guide shows the calculation, with a worked example for a small flat pergola.
1. Peak velocity pressure q<sub>p</sub>(z)
Everything starts from the basic wind velocity vb,0, read from the map of the National Annex of the country. With the direction and season factors (usually 1.0): vb = cdir · cseason · vb,0, and the basic pressure qb = ½ · ρ · vb², with ρ = 1.25 kg/m³.
- Roughness factor: cr(z) = kr · ln(z / z0), with z0 and kr from the terrain category (category II, open country: z0 = 0.05 m, kr = 0.19).
- Mean wind: vm(z) = cr(z) · co(z) · vb, with the orography factor co = 1.0 on flat ground.
- Turbulence intensity: Iv(z) = 1 / (co · ln(z / z0)).
- Peak pressure: qp(z) = [1 + 7 Iv(z)] · ½ · ρ · vm²(z).
2. Canopy force coefficients
For a canopy, EN 1991-1-4 gives the overall force coefficient cf (Table 7.6 for a monopitch roof, Table 7.7 for a duopitch roof) and local net pressure coefficients cp,net for the edge zones A, B and C, used to design the roof members and fixings. The values depend on the roof pitch α and on the blockage φ: how much the space under the roof is filled (φ = 0 empty, φ = 1 fully blocked, for example by stored goods, a parked car or closed side screens).
For a flat roof (α = 0°): cf = +0.2 downward, and upward −0.5 when φ = 0 but −1.3 when φ = 1. The overall force acts at d/4 from the windward edge, so the windward posts take more of it.
3. Worked example: a 3 × 4 m flat pergola
Free-standing pergola, flat roof 3 × 4 m (A = 12 m²) at z = 3 m, terrain category II, flat ground, vb,0 = 26 m/s (example value: use your National Annex), closed louvres acting as a roof, self-weight 0.25 kN/m² (G = 3.0 kN).
| Step | Calculation | Result |
|---|---|---|
| Basic pressure | qb = 0.5 × 1.25 × 26² | 0.42 kN/m² |
| Roughness and turbulence at 3 m | cr = 0.19 × ln(3/0.05) = 0.778; Iv = 1/ln(60) = 0.244 | vm = 20.2 m/s |
| Peak pressure | qp = (1 + 7 × 0.244) × 0.5 × 1.25 × 20.2² | 0.69 kN/m² |
| Downward force | +0.2 × 0.69 × 12 | 1.66 kN |
| Uplift, empty underneath (φ = 0) | −0.5 × 0.69 × 12 | −4.16 kN |
| Uplift, blocked underneath (φ = 1) | −1.3 × 0.69 × 12 | −10.81 kN |
| Design net uplift, φ = 0 | 1.5 × 4.16 − 0.9 × 3.0 | 3.5 kN |
| Design net uplift, φ = 1 | 1.5 × 10.81 − 0.9 × 3.0 | 13.5 kN |
The roof weighs 3 kN, but the design uplift reaches 13.5 kN when the space underneath can be blocked. That force goes through the posts into their base plates and anchors, and through the beams into any wall fixing. It is usually what governs a pergola. The dead load is taken with γG = 0.9 because it helps (EN 1990, Table A1.2(A)), and the wind with γQ = 1.5.
4. What else to check
- The local zones A, B and C (cp,net up to about 1.8 downward and −1.4 upward on a flat roof) for the purlins, louvres or panels and their fixings near the edges.
- Horizontal wind on posts, beams and side screens (section 7.6 for rectangular sections, friction on the roof in section 7.5).
- Snow on the roof (EN 1991-1-3), including drift against a building wall for a wall-attached pergola.
- The anchors into the floor or the wall, designed to EN 1992-4 with the uplift and shear from this calculation.
5. Do this calculation in PERGOLASOFT
PERGOLASOFT computes the wind on a pergola to EN 1991-1-4, sections 4.3 to 4.8 and 7.3, with the blockage, the canopy and local coefficients and the friction, adds snow and the other loads, checks the profiles and the connections, and designs the anchors with the ADIT anchor engine. It runs in your browser, and your project stays on your own computer.
This guide explains the method; it is not a design. Wind values depend on the National Annex of the country; every pergola must be designed and checked by a qualified engineer.