← Engineering guides

Post-installed rebar: anchorage length step by step (EN 1992-1-1)

When new concrete is connected to existing concrete, reinforcing bars are often bonded into drilled holes with injection resin. Designed as rebar, not as anchors, they follow the anchorage and lap rules of EN 1992-1-1, section 8.4 and 8.7, with the bond strength given in the European Technical Assessment (ETA) of the resin. This guide shows the calculation with a worked example.

1. Rebar or anchor? Choose the right method first

A post-installed bar is designed as rebar when it transfers its force by lap to the existing reinforcement, or is anchored where the existing member can take the force (end anchorage of a slab or beam). The concrete then fails only along the bar, and EN 1992-1-1 applies.

When the bar only holds a fixture and nothing in the existing member takes over its force, it is an anchor: the concrete can fail as a cone, and the design follows EN 1992-4 (see the anchor design guide).

2. The data you need

3. The formulas

4. Worked example: Ø16 starter bars into an existing slab

Ø16 bars, B500B, at full yield: σsd = fyd = 500 / 1.15 = 434.8 N/mm². Existing concrete C25/30, good bond conditions. The design bond strength used here, fbd,PIR = 2.7 N/mm², equals the cast-in value of EN 1992-1-1 for C25/30 (2.25 × 1.8 / 1.5); it is an illustrative value: take it from the ETA of the resin you install, for your drilling method.

StepCalculationResult
Basic required lengthlb,rqd = 16/4 × 434.8/2.7644 mm
Minimum lengthmax(0.3 × 644; 10 × 16; 100)193 mm
Design length, all α = 1lbd = 644 mm ≥ 193 mm644 mm
If the bar needs only 300 N/mm²lb,rqd = 16/4 × 300/2.7444 mm
Cover cd = 48 mm, if the ETA allows α2α2 = 1 − 0.15 × (48 − 16)/16 = 0.70451 mm
Lap with existing bars, α6 = 1.5l0 = 1.5 × 644966 mm

The drilled depth is the design length plus any part of the hole that is not counted (for example a damaged surface layer). Check it against the member thickness, the maximum embedment of the ETA, and the existing bars at the far face, which the drill must not reach.

5. What else to check

6. Do this calculation in ARS

ARS designs post-installed rebar connections to EN 1992-1-1: it computes the anchorage and lap lengths with the resin's bond values, checks the interface shear, fire, fatigue and seismic detailing, and gives the drilling depths, a drilling plan, the bar list and the resin quantity. It runs in your browser, and your project stays on your own computer.

Do this calculation in ARS, free in your browser →

This guide explains the method; it is not a design. Every connection must be designed and checked by a qualified engineer with the values of the ETA of the resin used.